A business can estimate the cost of solar downtime by comparing a hypothetical electricity purchase without the event with the actual purchase during it. Multiplying downtime hours by plant capacity is not enough. The calculation needs expected output for each interval, actual generation, site demand and the variable part of the purchase price.

The result is an estimate within stated assumptions, not a proven loss or insurance payment. The example below excludes storage and sales of surplus. Every value is invented and does not describe a real site, current tariff or ONG result.

Confirm the event and calculation boundary

First identify the start and end, time zone, interval length and affected part of the plant. A complete shutdown and reduced output from one inverter have different effects. Keep event logs, service records and other available evidence. Missing data in an app does not itself prove that generation stopped.

Select a common electrical boundary for expected and measured solar energy, such as an agreed point on the AC side. Do not compare a forecast at the module output with a measurement after unaccounted losses or with the business's total bill. Record units: energy is measured in kWh, while power is measured in kW.

The guide to forecast and actual solar generation explains weather data, matching periods and attribution of lost output. Use an agreed result of that technical check in the financial assessment and do not subtract the same loss again.

Estimate output without the event

The expectation should cover the same configuration, weather, time and measurement boundary as the actual data. Dividing an annual forecast by the hours in a year does not represent an actual solar day. One hour at night and one hour around noon have different generation potential. Ask a specialist to explain the model, weather inputs, included losses and limitations.

A neighboring day can help identify an anomaly, but differences in weather, temperature or shading mean it is not automatically an exact substitute. If reliable weather data are unavailable, record the gap and show a range of justified scenarios. Arbitrarily replacing missing measurements with zero creates false certainty.

For each interval, compare estimated output without the event with actual output, allowing for curtailment that would have occurred anyway. If the model instead reports potential before curtailment, label it accordingly: potential minus actual output is not necessarily lost generation. Neither estimate becomes measured merely because the arithmetic is correct. If several limitations overlap, agree how causes are allocated. Do not add two full estimates of the same difference.

Identify what the business could have used

Not every unavailable kWh would necessarily have replaced a grid purchase. Demand in an interval may be lower than potential solar generation. If export is excluded, surplus does not automatically have the value of purchased electricity. In the simple example without a battery, use the smaller of generation and site demand.

Compare hypothetical direct consumption without the event with actual direct consumption during it. The difference estimates additional grid purchases only under the assumptions that demand is unchanged in both cases, the grid is available and no other source supplies the load. Those assumptions may be inappropriate if production stopped because grid power was unavailable.

Interval length matters too. Averaging over a long period can hide short surplus periods and changes in demand. Use comparable intervals, state their duration and avoid implying more precision than the data support.

In the simple model, the purchase difference for each interval is min(potential, demand) - min(actual generation, demand). This assumes the values describe coincident flows; applying it to hourly totals is exact only when the within-hour timing supports that result. If potential and demand fluctuate, use shorter intervals or a justified range.

Identify the price actually avoided

For each interval, estimate how much the bill would fall if one less kWh were purchased. That variable value may differ from the average bill divided by total consumption. Charges that do not change with energy consumption should not automatically be multiplied by unavailable kWh.

Check the applicable price against the supply terms and settlement period. For example, electricity supply and any separately billed distribution or transmission component belong in the avoided rate only to the extent that the actual invoice and contracts make them vary with the additional kWh. Check who bills each component so it is not counted twice; demand-based or fixed charges need their own calculation. State whether values include VAT and use a consistent basis across scenarios. This article does not set a Ukrainian tariff. The business should check its own documents and ask its accountant about the applicable tax treatment.

An illustrative three-interval example

Assume each row represents one hour. At the same AC boundary, use the fictional figures below. The grid is available during all three hours, demand is unchanged between the two scenarios, and there is no battery or other source. Assume generation potential and demand are steady within each hour. The potential figures are before any export-limit curtailment; in the no-event scenario output is limited to simultaneous demand and surplus is neither produced nor sold. Assumed prices exclude VAT; fixed charges, repair costs and subsequent financial consequences are omitted.

IntervalAvailable potential before curtailment, kWhActual generation, kWhDemand, kWhAssumed variable price, UAH/kWh
11000606
28001207
37020355

Potential before curtailment minus actual generation is (100 - 0) + (80 - 0) + (70 - 20) = 230 kWh. This is a potential gap, not 230 kWh of lost output: without the event some potential would have been curtailed. In the first hour, however, the business could have used only 60 of the potential 100 kWh under the stated demand. In the second it could have used all 80. In the third, demand is 35 kWh and the actual plant already supplied 20.

IntervalAdditional purchase displaced, kWhCalculation, UAH
16060 × 6 = 360
28080 × 7 = 560
31515 × 5 = 75
Total155995

In this scenario, 155 kWh multiplied by the respective interval prices gives UAH 995 in estimated additional purchases. The difference between the 230 kWh potential gap and 155 kWh of displaced purchases is 75 kWh of potential that would be curtailed under these assumptions. It is not generated electricity or lost sales revenue. No sale value is assigned to it. The result is not the business's net loss and excludes repair costs.

Check three data sources

Each interval needs three comparable series: available potential before curtailment, measured output and total site demand. If the model already includes the curtailment that would occur without the event, do not apply the demand cap a second time without checking the balance. Agree how demand is derived if a meter shows only grid exchange. Net import is not always total consumption because some load may be served by onsite generation. Other sources require an agreed flow diagram and boundary.

Check interval start times and labels. A 10:00 record may refer to 10:00 to 11:00 or to the preceding hour, depending on the system. A one-interval shift changes results, especially when solar output and demand vary quickly. Check units and time zone, and determine whether a value is interval energy or a cumulative meter reading.

If a cumulative meter was reset or replaced, record the event before calculating differences between readings. A negative difference may result from a meter change rather than reverse flow. Mark missing rows and seek independent confirmation. Do not substitute another day's values without explaining the method and its limitations.

Report how many intervals have a confirmed event and how many have usable data. If demand is unavailable for two of four hypothetical hours, the result for the other two is not an estimate of the entire event. Leave the remaining hours open or build a clearly labelled scenario after agreeing assumptions.

Show limits and alternatives

Repeat the calculation with lower and higher justified estimates of potential generation, keeping other inputs unchanged. Separately review intervals with incomplete measurements and explain why they were included or excluded. The range may be wide if weather data or the event log are unreliable. Do not turn its midpoint into a confirmed fact.

If some solar energy could have been sold, that requires separately confirmed volumes, settlement terms and applicable costs. Do not value the same energy as both direct consumption and a sale. A battery or generator changes the balance and needs a different model, including charging sources and losses.

Keep additional purchase cost, repairs, any reimbursement and other consequences separate. Avoid double counting: an insurance payment should not simultaneously be treated as a repair-cost reduction and separate income without an explanation. Coverage and entitlement depend on the actual agreement.

An assessment of one incident can help compare next actions, but it does not establish the expected annual cost of future outages. An annual plan needs separate assumptions about frequency, seasonality, restoration time and uncertainty. One event is a useful observation, not proof that the same event will recur every year.

Prepare a reproducible report

Keep original records, time zone, plant configuration, weather basis, calculation formulas, price source and exclusions. Separate measured values from estimated inputs. Assign an owner and a next review date to each uncertainty.

The finance team can use the report to compare service scenarios or plan a reserve, and a technical specialist can investigate the cause. Compare response and reporting terms with the solar maintenance agreement checklist. A legal adviser and insurer review the documents if the business considers a claim. The table alone does not establish contractual responsibility or entitlement to payment.