Compressed air leaks can keep a compressor station running when the main production line is stopped. To understand their effect on electricity use, a business needs more than a list of leak locations. It also needs comparable operating records from before and after the repairs. A change in the electricity meter alone does not prove the saving came from leaks, because demand, pressure, equipment or controls may also have changed.

The practical decision for the energy manager and solar owner is whether a confirmed out-of-production air demand exists, how it changed after the work, and which station profile belongs in the energy model. The responsible site team carries out inspection and repair under its own procedures. This guide helps prepare and review the evidence. It is not an instruction for working on a pressurised system.

Define the air and electricity boundaries

Mark compressors, receivers, air drying, main distribution lines and air users on a current system diagram. Record which branches belong to the assessment, where pressure and flow are measured, whether the system has a permitted way to separate branches, and who is authorised to operate it. The diagram must describe the measurement period. A new branch, a changed receiver or an additional air source can change the comparison boundary.

Describe the electrical boundary separately. A meter may cover one compressor or the entire station, including dryer, ventilation and controls. If an individual compressor meter is already included in the station total, do not add it again. If auxiliaries are outside the meter, do not call the reading the complete energy use of the air system. Align units, intervals, time zones and any clock changes across the records before comparing them.

Receiver pressure, air flow and compressor electrical power describe different quantities. A pressure reading alone does not give kilowatt-hours. Electricity use does not directly reveal leak volume without a suitable model and relevant measurements. Keep the air and energy records independently, including gaps.

Distinguish leaks from useful demand

While the main line is stopped, other areas may still need air for controls, cleaning or auxiliary processes. Compressor operation during a weekend therefore does not automatically equal leakage. Ask the shift and process owners to confirm the status of every air user inside the selected boundary. If the status of one user is unknown, record that limitation instead of assuming its useful demand was zero.

For an estimate of total leakage, the responsible team may arrange a separate, agreed measurement when normal air demand within the boundary is known to be absent. The method depends on the compressor, its controls, the system volume and available instruments. Ask for a report identifying the boundary, pressures, time, operating conditions and assumptions. Do not compare two figures as equivalent if the included branches or flow units differ.

A survey can also identify individual suspected leak points. Keep that list separate from the system-wide estimate. The sum of point estimates depends on the survey method and the locations that were accessible. A missing detected signal does not prove that the entire network is airtight. A before-and-after comparison needs the same scope and appropriate conditions. Leave results with an unknown boundary open for clarification.

Connect the repair to the evidence

Keep a register of location, detection date, estimation method, repair status and post-repair verification for each point. Include a diagram version or branch identifier. Record other changes made between measurements, such as a new air consumer or modified compressor controls. A separate change may explain a difference even when the number of identified leak locations stays the same.

Select comparable intervals with the same production state. Check representative pressure records, which compressors were available, and whether the auxiliary equipment operated. Process specialists should confirm that required air quality and working conditions remained acceptable. A lower electricity reading while pressure was inadequate or a necessary dryer was switched off is not a valid demonstration of improvement.

Do not change pressure settings or control logic merely to improve the report. The allowed operating limits depend on the process and the equipment documentation. An authorised team owns the repair and functional verification. The investment owner needs a traceable record for the decision, without intervening in protective functions or asking operators to bypass normal procedures.

A hypothetical comparison of two shutdowns

Suppose a business compares two four-hour shutdowns, one before and one after repairs. Every number below is hypothetical. The electrical boundary is unchanged, normal air demand within the stated air boundary is confirmed absent, and pressure conditions and available equipment are assumed comparable. The meter includes the compressor station and dryer. It does not split the energy of individual devices or measure the leak volume.

IntervalBefore, kWhAfter, kWhDifference, kWh
Hour 11293
Hour 21183
Hour 31293
Hour 41183
Total463412

Before the work, station energy is 12 + 11 + 12 + 11 = 46 kWh. After it, the total is 9 + 8 + 9 + 8 = 34 kWh. The difference is 12 kWh over four hours, or an average of 3 kW across those windows. This is the measured station energy difference under the stated example conditions. It is not a separate meter reading for one leak, a benchmark for another factory or a guaranteed future saving.

Even in this example, do not multiply 3 kW by every hour in a year. The production calendar, station operating states and air demand vary. A longer estimate needs representative periods and an agreed method. If the dryer changed at the same time as the network repairs, the observed difference cannot all be assigned to the leak repair alone.

Use the result for solar and backup

A solar assessment needs an updated hourly or finer profile for the entire site. Sizing solar from a load profile starts with actual consumption, not the compressor nameplate rating. If the station is already included in the main meter, do not add its energy twice. Generation for a planned solar system is a forecast, not a measured result.

Review production shifts and shutdowns separately. Lower night demand does not imply an identical reduction in direct daytime use of solar generation. Compare simultaneous intervals for the whole site, including other loads and system constraints. When post-repair data are still limited, show the previous profile and a separate scenario, clearly marking the assumptions and the date for checking them against actual records.

For backup, identify which air users must operate during an outage, for how long, and with what pressure and quality requirements. Energy over an outage may change after repair, but starting and running power, auxiliary circuits and the available configuration remain separate checks. Do not select an inverter or generator using only the example average of 3 kW. The designer checks coincidence, motor starts and the limits of the actual power source.

The guide to unloaded compressor energy explains motor states in a report. The dryer metering guide helps define an auxiliary electrical boundary. As a commercial next step, send ONG Solar the diagram, agreed before-and-after profiles, critical air users and verification report. This lets the team assess solar or backup against the real process while keeping unknown values visible.

What to request for the next assessment

State the objective in the survey request: estimate air loss within a defined boundary and check how electrical demand changed after the repair. Ask the provider to distinguish the air-flow method from the electricity measurement. For flow, the units, reference conditions, duration and uncertainty matter. For energy, specify meter locations, active energy in kWh and interval times. Two reports with the same heading can otherwise describe different things.

Include planned changes at the facility. A new air user or fewer shifts can alter demand before a solar system is commissioned. Keep separate versions of the future profile: existing measured data, confirmed changes and a possible scenario that is not yet approved.

A monthly utility bill helps reconcile the site total, but it cannot identify compressor operation at night. Request available interval readings and equipment state records. If part of a shutdown is missing, show the gap. Do not replace it with zero or present an estimate as a meter reading. Compare the value of additional measurement with how much its result could change the equipment choice.

After the repeat check, agree who will update the system diagram and when the result will be reviewed. Networks and air users change over time, so one survey does not guarantee that demand will stay unchanged. A concise management record can separate three things: what was measured, what remains an assumption and what evidence is required before the final investment decision.