PVGIS azimuth: check the sign against the solar layout
Solar power systems

PVGIS azimuth: check the sign against the solar layout

Convert the bearing on an agreed drawing to a PVGIS 5.3 azimuth. Check the sign, module tilt and mode that will use these values.

ReadAll Articles
Illustration of a solar module on a support beside drawings and an unlabelled compass on white

Table of Contents

For a fixed plane in PVGIS 5.3, the azimuth is zero at south, -90 degrees at east and +90 at west. If an agreed drawing records direction clockwise from geographic north, convert the original bearing to this convention. Keep both values and check that they describe the same group of modules before running the calculation. If the north reference on the drawing is uncertain, leave the azimuth open for clarification.

Record the tool and the meaning of the original angle

Start with the calculation name and the version you are using. This check covers PVGIS 5.3 and the Grid-connected PV calculation for modules on a fixed mounting. Check the field definitions separately for another tool or mode. In the input worksheet, identify the module group, drawing revision and section that support the geometry. Each row should represent one agreed plane.

Locate the direction in which the module plane faces on the drawing. A building axis or a line along a row can describe a different direction. Ask the drawing author to confirm which arrow the angle belongs to. Record the origin, direction of increasing angle and unit. A value such as 120 becomes useful once its reference is explicit.

Use separate rows when the system has several orientations. An east-west label describes the arrangement in general terms. The actual planes can face different compass directions if the building is rotated. The guide to south-facing and east-west commercial solar covers the broader choice between configurations. Keep the agreed direction for each plane in the input worksheet.

Check what north means in the source drawing. The sheet may show a geographic north reference, a project axis or an arrow whose basis has not been explained. Retain its original label and ask the author to confirm the reference. A compass screenshot alone leaves that question open. The source date and revision matter both for the direction reference and for identifying the module group on the drawing.

Convert the bearing while keeping its origin and sign

For the source convention used here, geographic north is 0 degrees, east is 90, south is 180 and west is 270, with angles increasing clockwise. The azimuth in this PVGIS calculation is referenced to south. With those confirmed source conventions, subtract 180 degrees from the bearing on the drawing. Due south therefore becomes 180 − 180 = 0 degrees.

Check the sign using familiar directions. East becomes 90 − 180 = -90 degrees and west becomes 270 − 180 = +90. Southeast gives 135 − 180 = -45 and southwest gives 225 − 180 = +45. Write the direction in words beside the number so a later reviewer can see which side of south the value represents. Preserve the sign when transferring the input.

Keep the original bearing in its own column. In the next column, record the conversion and the value for the selected PVGIS field. In a PVcalc request, the fixed-plane azimuth parameter is named aspect. Its name helps identify the value actually sent. For directions near the wraparound point, check the permitted representation in the specific interface. The worked example below covers directions between east and west through south.

Then reverse the calculation. For the range used here, add 180 degrees to the PVGIS value and compare it with the original bearing. For instance, -45 + 180 = 135 returns the original southeast direction. If a source bearing of 135 has been converted to +45, reversing it gives 225 and identifies a field that needs correcting. The written compass direction provides a simple check before submitting the inputs.

Check the module plane against horizontal

Tilt in this calculation is the angle of the module plane from the horizontal plane. The PVcalc parameter is called angle. Use a section or another record that shows the modules and the reference line. Retain the roof pitch separately if it appears in the source documents, and identify the confirmed module tilt for the calculation.

If the modules are parallel to the roof plane, the drawing can confirm that their inclinations agree. If the mounting establishes a different plane, obtain the section for that arrangement. An angle on a bracket detail may be measured from the roof or from another surface. Check its reference before combining values. Ask the designer to state the resulting module tilt to horizontal and show which section supports it.

Check the units as well. A value in degrees and a percentage gradient describe different quantities. If the source shows only a roof gradient in percent, preserve it as the source record and ask for the confirmed module angle in degrees. The industrial rooftop shading guide explains the wider geometry and obstacle information needed for a shading review.

A fictional worksheet before entering values in PVGIS

All group labels and geometry values below are fictional. For groups A and B, the drawing author has confirmed clockwise bearings from geographic north. Group A faces a bearing of 120 degrees. Its section shows a roof pitch of 12 degrees and a separately defined module plane at 18 degrees to horizontal. Group B faces a bearing of 240 degrees with a confirmed module tilt of 12 degrees. These values illustrate input verification.

Fictional direction and tilt cross-check for fixed module groups
GroupDrawing bearingPVGIS azimuthModule tiltStatus
A120 degrees clockwise from north120 − 180 = -60 degrees18 degrees to horizontalChecked against the plan and section
B240 degrees in the same convention240 − 180 = +60 degrees12 degrees to horizontalChecked against the plan and section
CThe crop shows 120 degrees with an unconfirmed north arrowOpenOpen, section missingNeeds the source plan with its direction reference and a section

For A, -60 describes a direction 60 degrees east of south. For B, +60 describes the same angular offset west of south. The original values of 120 and 240 remain valid in their source column and are converted for the different reference. Keep A's roof pitch of 12 degrees in a note and use the confirmed 18-degree module plane in the tilt input.

The 120 label in C is insufficient to repeat that conversion. The crop does not establish north, and the angle could be referenced to a drawing axis. Assign the clarification to the drawing author and retain the row without a final value for submission. When confirmation arrives, record its reference and date before calculating the converted value. This gives the reviewer a traceable basis for the update.

Record who confirmed each ready row and where that evidence is stored. If a clarification affects C only, the verified A and B rows can remain in their existing worksheet version. If the author corrects the north reference for the whole drawing, review all groups that rely on it. A change to the source drawing can affect several converted values.

Check that the selected mode uses the entered geometry

Before submitting, establish whether the calculation is evaluating the stated geometry or searching for optimum angles. These are different settings in PVGIS. For the drawing check, record that the calculation uses a fixed plane with specified angles. If the team also wants a search for another tilt or orientation, retain it as a separately named scenario.

In PVcalc, setting optimalinclination to 1 requests an optimum tilt calculation and overrides the entered angle. Setting optimalangles to 1 requests optimum tilt and orientation, so the entered angle and aspect do not determine those angles in the calculation. Retain the mode with the input values. This helps explain a report that shows a different geometry from the one the team expected.

When values are transferred into a file or request, check the sign and decimal representation in the submitted fields. A short summary label can hide whether the value was entered manually, imported or produced by optimisation. Keep a copy of the agreed input set with its scenario ID. When the output retains the inputs, use them to check the worksheet and drawing together.

Hand over the checked fields with their references

Retain the tool version, mode, module group, internal document references, angle convention and original units. Beside these, show the converted azimuth, confirmed tilt and status of each field. After running the calculation, compare the geometry in the saved report with the worksheet. If values have changed, record why and retain the earlier version. The guide to forecast and measured solar generation covers the later comparison of output and measurements.

Region, coordinates, period, weather data, shading and system configuration affect the subsequent energy calculation. This check provides consistent geometry inputs for it. For solar design, supply the worksheet with the plan, sections and open questions. The team can then trace the direction and tilt of each fixed group to the inputs and output of a named scenario.

Questions about PVGIS azimuth and tilt