Table of Contents
Choose by airflow behind the modules
In PVGIS 5.3, choose free-standing when the modeled fixed modules are on a rack with air moving freely behind them. Choose building-integrated when modules form part of the roof or wall and air cannot move behind them. The choice changes the temperature assumption used to estimate PV performance. A panel being on a roof does not by itself establish which assumption best represents it.
Many roof arrays sit between those descriptions. A gap may exist but be partly enclosed by the roof, skirts, equipment or neighboring rows. For an early estimate, run both settings with the other inputs unchanged and record why the actual construction may fall between them. The two numbers are a sensitivity check, not proof that the real output must lie inside a guaranteed range. A site-specific design needs a supported baseline and its own treatment of uncertainty.
What the setting changes
Sunlight heats a module above the surrounding air temperature. Wind can remove some heat, while restricted airflow can leave the module hotter under the same conditions. Temperature affects the electrical efficiency used by the calculation. PVGIS combines weather and irradiance information with a module-temperature model and a performance model. The mounting field selects a set of thermal coefficients for the selected module technology. Structural strength and attachment details require separate assessment.
The model uses air temperature, wind speed and irradiance corrected for reflected light. It does not inspect a roof or measure the temperature of the proposed array. In practice the gap height, openings, array size and obstructions can affect air movement. The two available settings compress many possible arrangements into two simplified assumptions. Record the physical description alongside the selected option so a later reviewer can understand the choice without guessing from a checkbox.
Do not replace the input called system losses with the mounting setting. Entered system losses represent a separate aggregate assumption in the calculation. Adjusting that percentage merely to force one mounting result to match another would hide the reason for the difference. If a more detailed model is used for design, document its temperature and loss treatment explicitly to avoid counting the same effect twice.
A thermal example, not an energy forecast
The following arithmetic illustrates one condition for crystalline silicon modules. It is not a PVGIS annual output or a prediction for a particular building. Suppose the air is 25 °C, wind speed is 1 m/s and irradiance after the reflectivity correction is 1,000 W/m². In the temperature model, module temperature equals air temperature plus corrected irradiance divided by the expression U0 + U1 × W, where W denotes wind speed.
| Assumption | Coefficients U0 and U1 | Calculation | Model temperature |
|---|---|---|---|
| Free-standing | 26.9 and 6.2 | 25 + 1,000 / (26.9 + 6.2 × 1) | About 55.2 °C |
| Roof added or building integrated | 20.0 and 3.2 | 25 + 1,000 / (20.0 + 3.2 × 1) | About 68.1 °C |
For this chosen condition the difference is about 12.9 °C. That is a difference in modeled module temperature at one instant, not a percentage energy loss. Weather changes across hours and seasons, and the PV conversion model responds to more than temperature. It would be wrong to multiply this temperature difference by one guessed percentage and present the result as annual production. The coefficients and inputs are stated here so that the arithmetic can be reproduced.
Describe the actual mounting before choosing
Start with a section drawing or an installer’s description of the proposed assembly. Identify whether modules replace part of the weather envelope or sit above a separate covering. Mark the height and continuity of the rear gap where known, the open edges and any features that could restrict air movement. Record the drawing revision and whether the construction is confirmed or only proposed. Photographs can support the description of an existing roof, but they do not establish hidden details.
A rack standing above a flat roof may have substantial exposure, yet parapets and wind deflectors can affect its local airflow. A flush arrangement above a pitched roof may still have a ventilated gap. Neither the words “roof” and “ground” nor a single gap dimension automatically select a perfect coefficient. If the description is incomplete, show the two PVGIS cases and ask the design team for the details that would justify selecting one as the working assumption.
These checks concern an energy model. They do not determine whether a mounting system is safe for the roof or whether the roof is suitable. The support arrangement, wind actions, drainage and access need their own project assessment. Changing the PVGIS setting does not approve an attachment or alter the actual construction.
Run a controlled two-case comparison
Use the grid-connected fixed-system calculation for the same location, PVGIS version and radiation database. Enter the same installed peak power, module technology, system losses, horizon treatment, tilt and azimuth in both cases. Disable angle optimisation for this test: its purpose is to compare the same plane. Check the azimuth against the drawing before copying the geometry into the second case. Preserve the displayed inputs and the reported historical coverage with each result.
Change only the mounting field. In the API for the fixed calculation, the values are mountingplace=free and mountingplace=building. The documented default is free. Set the field explicitly even when using the default so the saved request communicates the assumption. If a tool version or dataset differs, record that fact and make a fresh matched pair rather than attributing every difference to mounting.
Label the results A and B. Record annual energy in kWh and the monthly energy in kWh for each case. Calculate B minus A for each matching field. If showing a percentage, divide that difference by A and state that A is the denominator. For example, if a hypothetical A were 1,000 kWh and B were 970 kWh, the difference would be -30 kWh or -3% of A. Those figures only demonstrate the worksheet. Keep the full precision of the export until the final display.
Compare the whole monthly series when timing matters to the decision. A difference in the annual total does not show which months drive it, and an average monthly figure is not a guaranteed result for any future month. Keep each run intact. Picking whichever monthly value looks better would create an unsupported third series. Likewise, an average of the two runs is a new assumption, not an automatic description of a roof with a partly open gap.
Keep the annual energy and irradiation fields distinct in the worksheet: kWh describes modeled electrical energy, while kWh/m² describes irradiation on the plane. Compare each field with its counterpart and inspect the saved inputs if the result is unexpected. A clear file name and calculation date make the pair easier to revisit.
Turn the comparison into a decision
Suppose a proposal uses the free-standing case but the section drawing leaves airflow unclear. Ask the author to identify the assumption, provide the second run and explain what evidence supports the baseline. If the difference has little effect on the choice being made, record that finding and retain both files. If it changes the preferred layout or financial conclusion, resolve the physical description and discuss a more detailed thermal assessment before relying on one number.
For multiple roof planes, give each group its own geometry and run the two mounting cases for that group. Add comparable groups consistently within each scenario. If the construction changes between groups, document which mounting assumption belongs to each one. A single site-wide label can conceal that one section is integrated while another has a raised rack.
Hand over the two exports, the comparison worksheet, the drawing revision and open questions to the solar design team. Mark which results are preliminary and who will confirm the mounting detail. Once operating measurements exist, compare like boundaries and time periods: a module sensor reading is an observation at its location, whereas this calculation is a modeled estimate. The record makes the choice reviewable when the design or the calculation is updated.