Weather Data Time in PVsyst 8.1
Solar power systems

Weather Data Time in PVsyst 8.1

Check UTC, seasonal time and interval labels before importing a weather series.

ReadAll Articles
Weather data logger and pyranometer on a white background

Table of Contents

Before importing weather data into PVsyst 8.1, check four things: the source time basis, any seasonal clock change, what each interval label means and any remaining time shift. Keep the original file and import settings. After conversion, check several intervals and the quality plots. This lets you align irradiance with the sun's position at the same time and explain where the weather file came from.

A time shift cannot be determined from one annual total. The same irradiation sum does not prove that values occupy the correct hours. A timing error can affect model calculations that use solar geometry. Its exact effect on yield requires a review of the file and another simulation.

What time a record represents

Weather series can use UTC, local time or another documented basis. Separately establish whether the source changes its clock during the year. For its internal weather series PVsyst uses the site's standard local time without seasonal clock changes. The source can use another convention, so describe it instead of guessing from the file name.

Another question is whether a label represents the beginning, end or middle of an interval. Average irradiance for a quarter-hour is not an instantaneous reading at the labelled time. The internal PVsyst label refers to the interval beginning. For a source labelled by the interval end, version 8.1 offers an appropriate import setting when the time step has been defined correctly.

This differs from aligning operating meter and monitoring series after commissioning. The guide to solar monitoring timestamps addresses those operational sources. Here the task is preparing a weather input for simulation and matching it to solar position in the relevant interval.

Why solar geometry matters

The model uses the sun's position for the corresponding interval. Under ordinary conditions PVsyst uses the middle of the interval. For intervals near sunrise or sunset, the official description adjusts that point using the portion of time when the sun is above the horizon. The label and calculation point are therefore not necessarily identical.

An incorrect time basis can shift measured irradiance relative to the calculated sun position. This matters for transposition to a tilted plane and other calculations that depend on solar geometry. A mismatch on a chart does not by itself identify the cause. Check the source documentation, site coordinates, time zone and sensor quality before changing a parameter.

Choosing a typical or historical year is a separate question. A typical series can combine representative months and does not describe the weather of one actual year. The guide to PVGIS weather series helps with that choice. Whichever is selected, the time convention and step must be known.

Four invented intervals

Imagine fictional average values for four quarter-hour intervals. The source labels each value by the end of the interval. The table shows the corresponding start. All numbers are invented, do not describe weather at a Ukrainian plant and are not program results.

End labelIntervalAverage irradianceIrradiation for 15 min
11:1511:00-11:15200 W/m²50 Wh/m²
11:3011:15-11:30400 W/m²100 Wh/m²
11:4511:30-11:45600 W/m²150 Wh/m²
12:0011:45-12:00400 W/m²100 Wh/m²
Total11:00-12:00Four intervals400 Wh/m²

Multiply each average irradiance by 0.25 hours. The total is 50 + 100 + 150 + 100 = 400 Wh/m², or 0.4 kWh/m² for the hour. If the end labels are mistakenly treated as interval beginnings and only labels from 11:00 through 11:45 are summed for this hour, the first three values are included. They give 300 Wh/m². The fourth record is incorrectly placed in the next hour.

The 100 Wh/m² difference in this hour results from grouping in the example. It is not sunlight lost over the entire period. If all four records remain, their combined total is unchanged. The example does not determine a time-shift sign for every format. Check the sign and import rules against the documentation of the installed version.

Describe the source

For each file record the provider, coordinates or site name, units, period, time step and how the data were produced. State whether they are measurements, satellite estimates or a synthetic series where known. Identify the time basis, seasonal clock convention and which part of the interval the label names.

Check whether every column uses the same step and labelling. Temperature may be instantaneous while irradiance is an interval average. Do not assume identical meanings without the source description. If the information conflicts, leave the question open and request an explanation before the final import.

Record the expected number of rows, gaps, duplicates and unusual values separately. A missing record is not automatically zero sunlight. Any exclusion, correction or replacement must be reproducible. Preserve the original file unchanged and label the processed version with its date and reason.

Separate conversion from validation

PVsyst 8.1 documentation describes separate settings for UTC, seasonal time, interval label and remaining shift. Apply them according to the actual source convention. Do not add a manual shift that repeats a conversion already made. Agree the site coordinates and time zone before calculation because the conversion to the internal scale depends on them.

After import an analyst can compare the best clear-day plots and morning and afternoon distributions with a clear-sky model. These plots can reveal a systematic shift but do not replace the original time description. If the apparent offset varies through the year, investigate a possible seasonal clock change or another cause before applying one constant correction.

Version 8.1 changed time-shift handling relative to older releases. Part of a shift can change timestamps, while a remainder corrects solar position. Read the source setting and the resulting file value using documentation for the version actually used. Do not transfer a sign or field name from an old report without checking it.

Review seasonal transitions

Choose examples from different parts of the year, not just one clear day. Beside each source label record its interval and converted model-file time. If the source uses seasonal time, check the actual transition dates in that dataset's documentation. Do not assume another year or source follows identical rules.

Local timestamps can repeat or be absent around a transition. Establish how the provider distinguishes duplicates and whether the source information establishes their order. If it does not, document the uncertainty and ask for clarification. Renaming two different records as one time without explanation can lose data, while automatic gap filling can introduce an unsupported value.

UTC conversion also needs the correct site. Establish the source scale and import rules before adding any manual adjustment. Check the program version even when the result looks plausible.

Check boundaries and resolution

A sub-hourly shift can change which records fall into a given hour. It does not follow that every daily or annual total will remain identical in every file. Edge records, gaps and processing rules also matter. Ask the analyst to check the first and last intervals and show separately how values outside the period were handled.

Compare average irradiance in W/m² with an average quantity, and accumulated irradiation in kWh/m² with energy per area for the same period. Converting average power to energy requires the duration in hours. Do not add power values as energy without that step, or reuse a multiplier for files with different recording frequencies.

If the original file has hourly values, repeating each value four times does not recover real variation inside the hour. The finer table then represents an assumption, not a new measurement. Distinguish measured resolution from simulation step in the report and explain transformations performed.

Compare two imports

When the time basis is uncertain, preserve two clearly named import variants and change only the disputed setting. Use the same source file and plant configuration for both. Reconcile several documented intervals and review clear-day checks before comparing annual yield. This helps identify which input difference produced the change.

If a discrepancy remains after checking time, do not tune the file to obtain a desired result. Coordinates, measurement quality, sensor shading or other source characteristics may explain it. A separate analyst conclusion should list explanations checked. When evidence is insufficient, a limited conclusion is a valid result.

Hand over the forecast

Request the source weather file, source description, import settings, program version and resulting model file. Add examples of reconciled intervals before and after conversion, units and the quality-check result. Record questions the provider has not answered and who will resolve them.

After the plant starts operating, forecast and measurements can be compared using matched boundaries and suitable time series. The guide to forecast versus actual generation explains that task. To review a specific model, provide ONG Solar with the weather files, site description and decision the calculation should support. The scope is agreed separately.

Weather time questions

Ready for energy independence?