PVsyst IL_Imax: Current and Power
Solar power systems

PVsyst IL_Imax: Current and Power

Read zero modelled current loss alongside the inverter power limit.

ReadAll Articles
Multi-channel solar inverter on a white background

Table of Contents

In a PVsyst report, a zero IL_Imax entry does not prove that an actual inverter's current requirements are satisfied. It means that under the specified conditions the model did not attribute energy to maximum-input-current loss. A power limit can change the operating point first, with the associated modelled loss appearing in IL_Pmax. Review both entries, the inverter file and configuration at a common boundary.

This is an interpretation of a calculation, not a conclusion that a physical connection is safe. Permitted operating current, short-circuit current and other limits have different definitions. Check them for the particular supply against applicable manufacturer documents and the project diagram. Responsible specialists perform work and measurements on the installation.

Which entries are compared?

In the model the inverter seeks an array operating point while accounting for power, voltage and current limits. If the available maximum-power point lies outside one limit, the model determines another operating point according to its method. The power difference across simulation intervals forms the corresponding energy loss.

IL_Pmax concerns loss associated with nominal power limiting, while IL_Imax is associated with maximum input current. Check names and result composition for the version that produced the report. Other entries can describe voltage limits or a power threshold. They answer different questions, so do not substitute one for another merely because both are called losses.

The PVsyst loss diagram explains the overall sequence and changing bases. The practical task here is narrower: trace which limit was active in specified intervals and what a zero entry does not establish.

Why power can limit first

According to the PVsyst model description, power limiting shifts the operating point along the array characteristic. If current at the new point is already below the modelled current limit, a separate current loss may not arise for that step. This does not mean that the available point had the same current before limiting or that another configuration will behave identically.

Changing available power, voltage or channel allocation can change which limit is active. An actual comparison needs the modelled array characteristic and exact inverter file. Do not estimate annual losses from a single STC current alone. Likewise, zero modelled loss does not waive separate datasheet requirements.

Nominal power allocation between modelled inputs can also affect results. Ask which channels and sub-arrays belong to one physical inverter. Do not treat a total entry as proof for each input if the project does not preserve the relevant breakdown. The physical diagram and manufacturer documents are reviewed separately.

Two fictional operating points

The following simplified teaching data concern one fifteen-minute step. The fictional available point is 600 V, 33.33 A and approximately 20 kW. Both cases use a modelled current limit of 30 A. Other limits are assumed inactive for illustration. This is not a product specification, a configuration recommendation or an actual PVsyst result.

QuantityCase ACase B
Modelled DC power limit15 kW20.5 kW
Assumed operating point650 V and 23.08 A610 V and 30 A
Point powerAbout 15 kW18.3 kW
Active limit by assumptionPowerCurrent

In A, 650 × 23.08 / 1000 gives approximately 15.00 kW. By assumption the point reaches the power limit while its current is below 30 A. The difference from the fictional 20 kW is about 5 kW, or 1.25 kWh over 0.25 hours. For this example it is attributed to the power limit.

In B, 610 × 30 / 1000 = 18.3 kW. Current reaches the specified 30 A while power is below the fictional 20.5 kW limit. The difference from 20 kW is 1.7 kW, or 0.425 kWh over a quarter-hour. By assumption it is attributed to the current limit. The two points are specified to explain accounting. A real calculation needs the actual characteristic and all active constraints checked.

In both cases the fictional available point had current above 30 A. Yet in A a separate current entry can be zero for that step because the assumed power limit applies first. This does not prove that any inverter permits such an array. The comparison establishes neither annual generation nor warranty terms.

Separate model and datasheet

Operating current at maximum power and short-circuit current are different quantities. A parameter can also apply to one connector, one MPPT or the whole device. Retain the manufacturer's name, units, conditions and notes. Do not compare numbers at different boundaries or modes simply because both use amperes.

Compatibility review also includes voltage, temperature, string count and distribution, and other requirements. The guide to inverter and panel compatibility addresses those separate checks. This article gives no permitted module count or universal margin. A missing parameter remains an open question until applicable documentation is received.

In an inverter file, current limit can be specified directly or determined from other model parameters, as described in the program help. Ask the analyst to show the field's source and interpretation for the relevant version. Do not transfer a value from a similar series or another market without confirmation.

Compare two calculations

Keep the original equipment file, PVsyst version, array composition, sub-array diagram and weather series. For the second variant change only the agreed model assumption if the purpose is to test its influence. Other limits, step, orientation, losses and output boundary should stay the same. If a curve or another parameter also changed, describe that as an additional change.

Find intervals with high available power or a visible current limit. Compare available and operating points, loss names and units. Do not add percentages with different bases without identifying each denominator. If only rounded annual results are available, request a detailed export or an explanation of which conclusions the report supports.

One simulation step is an example, not annual statistics. Total energy depends on weather, duration and other constraints. For a broader power comparison see DC/AC ratio and clipping. That guide addresses the total limit, while this one checks the meaning of two separate loss entries.

Review the inverter file

Record full product code, suffix, datasheet revision and model-file date. Beside each field retain its name, value, unit and source document. Establish whether the value is a direct input or calculated by the program from other parameters. A result based on an unconfirmed file remains a scenario.

When comparing equipment revisions, first list all differences. A file name change does not prove the remaining characteristics match. The rating, MPPT modelling method or voltage limit may also change. An isolated test needs one understood change. A complete comparison of two products should be named accordingly.

When a manufacturer specifies a limit for a channel, reconcile it with the string schedule and exact device version. Request written clarification if information is missing. A zero report entry cannot replace that confirmation. The model database record and documentation applicable to a Ukrainian supply can serve different purposes.

Compare interval records

For selected control intervals record available array power and voltage, the modelled operating point, limits and the relevant loss entry. Clarify which quantities the program exports directly and which the analyst calculated separately. If values for individual MPPT inputs are unavailable, do not present the plant total as each channel's result.

Power in kW and energy accumulated over an interval in kWh have different units. For constant power, energy equals power multiplied by duration in hours. Each interval in the table lasts 0.25 hours. A different duration would give different energy for the same power difference.

Check matched timestamps, completeness and rounding. A zero in a PDF may be a rounded display of a small quantity, while an absent field does not always mean zero. Request absolute values with adequate precision and an export description. Preserve source files and explanations together so the comparison can be repeated.

If the model and datasheet still conflict, leave the discrepancy open. Record which document or repeat calculation can resolve it. A change made only to make a chart look favorable does not establish the equipment's capabilities.

Use the conclusion

If the current entry is zero, ask whether model inputs, time step and input representation could reveal the situation. Show IL_Pmax and other active limits alongside it. Do not call the absence of a separate modelled loss proof of no losses or manufacturer approval.

Provide ONG Solar with the report, inverter file, program version, input diagram and exact product datasheet. Add control intervals, parameter sources and open questions. A physical configuration conclusion needs a separate review of the site's documents and does not follow automatically from this teaching table.