Read the two shading effects separately

A PVsyst report can show a near-shading irradiance deficit and an additional electrical shading loss. The first describes light blocked from reaching the array in the model. The second describes extra mismatch associated with the electrical response of unevenly illuminated modules and strings. To review the result, check the 3D scene, the selected electrical method and the string assumptions together. A shaded surface percentage alone cannot establish the electrical loss.

Decide whether the method and its inputs adequately represent the proposed plant. Ask for the variant file, the scene and an explanation of the model, not just the annual total. A small or zero electrical entry can reflect a selected method or assumption as well as the simulated conditions. It is not proof that shade has no electrical effect.

This guide concerns near shadings in a grid-connected PVsyst project. For the complete sequence of energy nodes and units, use the PVsyst loss diagram guide. For surveying actual obstructions, see the separate guide to industrial rooftop shading.

What each loss represents

The geometric scene places tables and obstacles in relation to the sun. PVsyst calculates shading factors and the associated irradiance deficit. Its glossary describes linear shading as the sum of contributions on direct beam, diffuse and ground-reflected light. These components are not all represented in the same way. The current software treatment and options depend on the model and version, so ask the analyst which settings apply to the actual report.

Electrical mismatch is an additional effect during conversion to power. Cells and modules connected in series share current, while parallel strings share an operating voltage at their MPPT input. Unequal illumination can change the combined current-voltage curve and the available maximum power. Bypass diodes can provide a path around affected cell groups under appropriate conditions, but do not restore the blocked light.

PVsyst's detailed calculation separates the geometric contribution from the remaining electrical contribution. The separation is part of its model, not a second independent measurement of a real plant. A visible shadow on a few cells does not automatically mean the entire plant stops, and an equal shaded area in two pictures does not establish equal power loss. Position, connections and the rest of the operating conditions matter.

Make a report review sheet

Record the report date, software version, variant, site and weather file. Alongside the shading lines, record their values, units, sign, calculation basis and the surrounding energy or irradiation node. A percentage in one part of the loss diagram need not have the same denominator as a percentage in another. Do not add the two percentages as if both referred to the same original energy.

ItemEvidence to requestQuestion
Scene3D file, dimensions and revisionAre tables and relevant obstacles represented?
Irradiance deficitMethod and report nodeWhich light components and period are included?
Electrical lossSelected method and settingsIs this additional mismatch or only linear shading?
ConnectionsModule layout, strings and MPPT assignmentDo inputs match the proposed circuit?
ComparisonVariant change log and output boundaryWas the method or more than one input changed?

Leave an unknown setting marked as unknown. An absent line may mean the effect was not calculated, is displayed elsewhere or is negligible under the selected conditions. The report author should identify which explanation applies. Record the answer with the version rather than inferring it from a blank field.

Check the scene before the method

A detailed electrical calculation cannot repair an inaccurate shadow geometry. Compare the 3D scene with the current site drawing: table positions, dimensions, orientations, heights and relevant nearby objects. Verify the coordinate and height references used in both documents. An obstruction omitted from the scene cannot cast its actual modeled shadow, however detailed the electrical settings appear.

Ask to see several time-stamped views of shadow movement and the corresponding module surfaces. These snapshots are a check of the scene, not a substitute for the full time-series calculation. A long shadow at a particular hour does not alone determine annual loss. Irradiance, time of year and the affected electrical grouping also matter.

Distinguish the distant horizon from near objects and record how each is represented. If a measurement is uncertain, mark the range and its source. Request a controlled sensitivity run when that uncertainty could change the decision. Retain each scene revision and its simulation identifier so that an updated drawing does not become confused with an older result.

Understand the partition approximation

The option commonly called according to module strings uses partitions on the tables in the 3D scene. These rectangles approximate areas affected electrically by a shade. The method estimates the electrical effect quickly and is particularly suited to regular mutual shading in row arrangements. It is an approximation, not a reconstruction of every module's actual current-voltage curve.

Review the partition dimensions and placement against the physical module orientation and intended electrical grouping. A partition is not automatically one module. Ask how the rectangles correspond to the layout. Verify the partitioning of each relevant field, rather than assuming that one setting covers differently arranged tables.

The method also uses a fraction for the electrical effect. It changes the calculated electrical contribution and needs a defensible basis. A smaller value is not a measured improvement. Keep the chosen value, its justification and the version of the model in the handover. Where shading is irregular, ask whether this approximation remains suitable and what comparison can test it.

Understand the detailed Module Layout

Module Layout requires the positions of individual modules in the 3D scene and their allocation to strings, sub-arrays and inverter inputs defined in the system. The simulation combines module electrical characteristics within strings and strings at each MPPT input. This makes it possible to examine the effect of the specified electrical interconnection, not merely the extent of a shaded rectangle.

Detailed does not mean automatically correct. Match module count and positions to the current design. Check the actual string map, module orientation and MPPT grouping against the electrical plan. If the proposed connection changes, the old layout is no longer evidence for the revised circuit. Ask for a new version and retain the prior one for comparison.

Documented limitations matter. The tool is intended for crystalline modules with usual rectangular cells and does not represent thin-film behavior in the same way. The documentation also warns that long, thin shadows such as poles may be underestimated because of how shaded submodules are recognized. For those objects, ask the analyst to examine the partition approach and its own assumptions rather than treating either method as an unquestionable answer.

Detailed calculation can be computationally demanding. PVsyst documents size warnings and a possible representative subsystem comparison for large projects. Such a subsystem must be justified as representative of the shading and electrical arrangement. Results for one convenient corner of a field should not automatically be applied to a different geometry.

Compare a defined pair of variants

Imagine a fictional row-based array with a fixed scene and unchanged weather file. A base variant uses linear shading only. A second uses the same geometry but enables an electrical shading method with documented partitioning. No numerical output is assumed. Compare corresponding irradiation and energy nodes and ask the author to explain any changes in their bases and allocation.

The second run addresses an additional modeled electrical effect. Its difference from the first is a difference between those two defined simulations, not a measurement or guaranteed energy saving. If the analyst also changes module type, table spacing or inverter assignment, the change cannot be attributed solely to the shading method. Request a further controlled comparison or label the result as a combined change.

A separate comparison between partition and Module Layout must use a suitable common scene and system definition. Differences can arise from method assumptions, partition settings, module positions and electrical connections. Ask which method suits the site and available data. The lowest loss is not by itself the most credible model.

Keep the result reproducible

Request the simulation report and project files, 3D scene, system definition, method selection, partitions or module layout, and supporting drawings. Add a list of assumptions and unresolved questions with a responsible person. A screenshot of the final number cannot reproduce the model.

When comparing proposals, align the weather data, modeled period, capacity, orientation, geometry and electrical output boundary. Confirm the versions and disclose every material change. If a report uses only linear shading, state that clearly instead of calling it a complete electrical assessment. If an obstruction, layout or string plan changes before construction, ask the designer whether a fresh simulation is needed.

After installation, retain the constructed layout and compare it with the modeled arrangement. Actual measurements, event records and weather data can support a later investigation, but the model's two loss rows are not direct measurements of field losses. A forecast versus actual review explains how to align those records before assigning a cause.