How to Check a PVsyst PAN File
Solar power systems

How to Check a PVsyst PAN File

Reconcile module identity, parameter sources and file version for a yield forecast.

ReadAll Articles
Solar module and electronic meter on a white background

Table of Contents

Before using a PAN file in PVsyst, reconcile the full module code, datasheet revision and the file's origin. Compare basic characteristics under the same conditions and establish which additional parameters are measured, supplied by the manufacturer or estimated by the model. Keep a copy with the program and project version. Matching names or nominal power alone does not prove that the file represents the proposed supply.

A PAN describes a component for modelling, not a measurement of every supplied module. It also does not establish product availability, warranty or identical conditions in Ukraine. If the datasheet, file and project specification conflict, record the discrepancy and request applicable documents before approving the forecast.

What the component model stores

The PVsyst module database uses identifiers, basic electrical characteristics, dimensions and model parameters. A PAN file can contain a created or modified component record exchanged among project participants. The file name helps locate it, but a shortened name may omit product suffixes or the document revision.

Ask the analyst for the full code, file source and date received. Compare them with the agreed specification and datasheet for that version. If the module was substituted after the model was prepared, an old copy may no longer describe the proposed equipment. Preserve both versions and the reason for change rather than renaming the old file as the new model.

The guide to STC, NOCT and NMOT explains nameplate and operating conditions. The separate question here is whether a model file can be traced to the specific product and whether other inputs have known origins.

Reconcile basic quantities

List nominal power, voltage and current at maximum power, open-circuit voltage and short-circuit current. Beside each group record irradiance, temperature and source revision. Comparing numbers at different conditions without adjustment does not establish an error. Check units, rounding and temperature coefficients too.

Nominal power in the database and the product of specified voltage and current can differ slightly because of rounding or inconsistencies in source specifications. The internal model's standard-condition result may also differ slightly from the nameplate value. A material discrepancy needs explanation, not a silent correction. The product alone does not validate the rest of the model.

For teaching, imagine a fictional record with Vmp = 40 V and Imp = 10 A. Their product is 400 W. If the adjacent nameplate value is 402 W, the arithmetic difference is 2 W, or approximately 0.50% of 402 W. This is not an actual product specification or an acceptable threshold. Request the source document and an explanation of rounding or conditions before identifying the cause.

A file review schedule

The following table is a structure for questions, not a completed specification. Keep the exact file and supporting document for each row. If confirmation is missing, leave the status open. Do not invent an absent parameter just to finish the comparison.

CheckEvidenceQuestion
Product codeSpecification and datasheetDo suffix and version match?
PAN fileOrigin and dateWho created or changed the record?
Basic quantitiesConditions and revisionAre units and bases consistent?
Other parametersMethod and inputsMeasured or model-estimated?
ProjectVersion and chosen copyWas that file used in the report?

If a supplier provides several similarly named files, do not choose the newest only by its computer creation date. Establish which file is intended for the exact module and what changed. A file checksum or another agreed identifier can distinguish copies, but does not prove that their contents are correct.

Model data and assumptions

The model needs more than basic datasheet points. Some additional parameters are not always in a normal datasheet and may be determined using assumptions. PVsyst documentation describes series and shunt resistance among them. Do not transfer their values between different modules as confirmed characteristics without a basis.

If low-irradiance measurements were used, establish conditions, temperature, test method and whether the sample matches the specified model. The software can show points and the model response for review. A difference between them is a question for the parameter author, not automatic proof of a defective supply. Ask which points were actually entered and which are model results.

The separate guide to panel performance at 200 W/m² explains relative figures and their limits. Here the task is tracing such data to a particular PAN and its parameters. One verified point does not validate the complete range or a system's annual output.

Separate the file from the batch

A nameplate component model may be common to many modules in a project. A batch flash test serves another purpose and concerns specific products and test conditions. Comparing measurements with nameplate power can support a separate module-quality assumption, but it does not establish the provenance of every PAN parameter. Retain the documents separately.

Do not call a modelled value a warranty requirement. A warranty enquiry needs the particular supply terms, applicable documentation and an agreed verification method. Likewise, the absence of another point from a short datasheet does not prove poorer module performance. Mark the gap and request the data needed for the decision.

The software database can retain older components for old projects. A listing does not establish current availability. Reconcile the current datasheet and product version, while confirming availability and terms for Ukraine separately. Do not transfer conclusions from another country or an adjacent product series.

Compare two versions

Keep the original PAN and a differently named copy for each agreed variant. Record which fields changed, who changed them and which document supported the change. If only the component file changed, hold module count, weather, inverter, configuration and other assumptions constant. A result difference can then be read as sensitivity to that model change.

If a new product has different dimensions or electrical limits, the review covers more than one parameter. A separate configuration and renewed compatibility assessment are needed. Do not call a higher forecast proof of better module quality before checking common conditions and input sources.

Compare results at the same energy boundary and period. Request more than the annual total and ask which model characteristics caused the difference. The PVsyst loss diagram helps trace the overall sequence, but does not validate the file itself. Data from an operating plant remain a separate check.

Trace each parameter

For each important field record both the value and its source: manufacturer datasheet, separate report, software assumption or model author's decision. These categories are not equivalent. If a document does not show a parameter, do not call it measured simply because it has many decimal places.

Ask whether a report concerns the same model, technology, batch or only one sample. Keep date, method, conditions and scope. A point obtained at another temperature or irradiance does not directly confirm a standard-condition value without an explained conversion. The analyst should show how the data were used.

When the source is a software assumption, record the version and reason for accepting it. A database or software update can change the available record. Compare old and new components by named fields and rerun the calculation with other inputs unchanged when the difference matters. Do not assume a newer record is more accurate without checking its source.

Recheck after a change

After a panel substitution, check more than the nameplate rating. Dimensions can change the number on a plane, while electrical characteristics can affect the permissible string design. Layout, inverter and voltage data need separate review against documentation. Matching one PAN point to a datasheet does not close those questions.

Ask the model author to confirm which copy is included in the final project and whether it matches the approved equipment. When another team receives the file, retain its identifier, date, software version and a way to reproduce the calculation. Independent review is possible only when the same inputs are available.

If some parameters remain unknown, show the effect of a defensible range in separate scenarios. Do not select a value solely because it gives the largest yield. The conclusion should name the assumptions, energy boundary and information needed to refine it. State whether laboratory data for the proposed version are available and who will clarify missing evidence.

Hand over the forecast

Include the approved module code, datasheet and revision, PAN, source, change list and software version. Add unknown parameters, measurement documents and the comparison description. Record which copy was used in the final project variant.

To discuss a calculation with ONG Solar, provide the package and a specific question, such as the effect of replacing a file on the forecast. Ask the team to separate confirmed data from model assumptions and state the conclusion's limits. The scope is agreed for the individual plant.

PAN file questions

Ready for energy independence?