To explain IL_Vmin or IL_Vmax in PVsyst, find the intervals where the array's unconstrained maximum power voltage sits outside the inverter's MPPT window. Match those intervals to the inverter definition, the array current-voltage curve and the other loss categories. For a yield review, the question is what power the model can deliver once the voltage boundary applies. The maximum permitted open-circuit voltage belongs in a separate design check.
Where the model moves the operating point
The inverter model searches for the point of maximum power on the current-voltage curve. The VmppMin and VmppMax values define the tracking window. If the unconstrained point is outside it, the outcome depends on the strategy. In Limitation mode, the model works at the applicable voltage boundary and uses the power available on the curve there. In Cut mode, the model stops inverter production under that condition. With identical array inputs, these strategies can produce different energy losses.
When the ideal operating voltage is below the lower bound, the corresponding loss is IL_Vmin. When it is above the upper bound, the row is IL_Vmax. For a stable interval, the difference in power multiplied by the interval duration gives energy lost. Annual results aggregate those events. To explain a particular loss, examine its timing and establish whether it applies to one input, several groups or a wider system calculation. A single annual percentage hides this distribution.
Check what evidence identifies the strategy for the actual inverter variant. Product families can have multiple versions. Match the component identifier with the applicable manufacturer documentation. Where the behaviour beyond the tracking window cannot be established from the evidence, record the model setting as an assumption. A documented sensitivity case can show whether the decision depends on it. Simulation alone cannot confirm how the physical device responds to an undocumented condition.
Identify the voltage checks
The tracking window, the maximum permitted DC voltage and the minimum voltage for full nominal power describe different limits. Compare VmppMin and VmppMax with the array operating point. Compare an absolute maximum with open-circuit voltage for the design conditions, including the applicable low temperature. An inverter can need an additional condition to obtain full rated power within the tracking range because of a current constraint. Record the exact field and its units with the source.
| Fields | Value to check | Purpose |
|---|---|---|
| VmppMin, VmppMax | Array MPP voltage over selected intervals | Explain IL_Vmin or IL_Vmax |
| VAbsMax | Open-circuit voltage at site design conditions | Check the absolute DC input limit |
| Vmin_Pmax | Documented conditions for nominal power | Explore current limits at low voltage |
| IL_Pmin, IL_Pmax | Minimum operating power and overload loss | Distinguish other loss mechanisms |
Check the string layout, the relevant module data and the design temperatures when reviewing the cold open-circuit case. Confirm which module and inverter revisions are represented. A field procedure is a separate task. The article on open-circuit voltage test reports explains how existing results are tied to individual strings and observed conditions. An MPPT voltage loss in a model does not show that the absolute voltage limit is exceeded. Conversely, a year with no IL_Vmin or IL_Vmax does not supply the separate worst-condition voltage proof.
Some documents list a minimum voltage for full inverter output separately from the tracking minimum. Review IL_Imax and the current and power limits when this distinction affects the estimate. Also check the input power threshold at low generation. If the unit cannot operate because available input power is below that threshold, the event belongs to a different mechanism. Keep the relevant power, voltage and state information together when deciding which event to inspect.
A two-interval power comparison
Take two hypothetical current-voltage curves from two different intervals. In the first, the unconstrained maximum is at 340 V and 18 A. At the lower boundary of 360 V, current is 16 A. In the second, the maximum is at 780 V and 9 A. At its upper boundary of 760 V, current is 9.1 A. Limitation mode applies throughout the example, and no other limits are active. These are illustrative circuit values with no approved setpoints or equipment ratings implied.
In the first interval, 340 × 18 = 6,120 W, compared with 360 × 16 = 5,760 W at the permitted point. The difference of 360 W over two stable hours gives 0.72 kWh. In the second interval, 780 × 9 = 7,020 W and 760 × 9.1 = 6,916 W. A loss of 104 W lasting half an hour gives 0.052 kWh. Each new voltage needs its own current from the curve. Reusing the unconstrained current at the new point would misstate the available power.
Now consider Cut mode for the first interval. With no simulated production, the lost potential in the simplified example is the whole 6.12 kW for two hours, or 12.24 kWh. This comparison demonstrates why the mode deserves explicit attention. When using actual equipment models, verify the strategy and conditions against their documentation and keep the other simulation inputs fixed. The two modes are scenario choices only where the intended behaviour has been established.
Review the time-series evidence
Keep the original variant, inverter definition, input assignments and source weather. When exporting results, identify whether each power and voltage series belongs to the array, an MPPT input or the whole inverter. Ask the modeller which voltage represents the unbounded MPP and which represents the actual calculated operating point. Review the intervals that contribute to IL_Vmin and IL_Vmax and identify other limits active in those intervals.
An average operating voltage cannot show how many short periods fell outside the window. Two reporting periods can have comparable energy yet different voltage or current profiles. Check the simulation step and the resolution of the source data. If the problem is observed only inside a short interval, consider whether the chosen export can represent it. Compare all reported loss terms at consistent energy boundaries so a loss already included in a grouped result is not added twice.
Change one defensible input
Keep the weather, geometry, electrical model and power boundary the same for a controlled test. Then change one supported assumption. If a second layout uses a different string length, installed DC capacity and inverter, describe those changes. A shift in several loss lines could follow from more than one cause. Use the PVsyst loss diagram alongside the interval data to trace which energy boundary each line represents.
Avoid fitting an inverter's tracking window to a preferred annual figure. The applicable equipment documents and configuration should establish the range. If two component records disagree, hold them as separate scenarios and obtain the relevant manufacturer confirmation. The loss difference can then be judged with its uncertainty visible. Documented limiting behaviour supports design decisions when combined with the separate checks of equipment ratings and site conditions.
Prepare a list of the intervals that contribute most to the annual voltage-window loss. Record the duration, model variant and input group alongside each observation. A yearly percentage should have an identified denominator. If energy lost is similar while the percentage changes, examine the reporting base and the count of valid intervals before treating the change as a design improvement. Separate the cold design check from the operating evidence in the handover so the two tasks can be repeated from the correct input conditions.
Prepare the design handover
For commercial solar design, provide the exact inverter documentation, available module information, string assignments and site temperature assumptions. List the losses already reproduced and the questions still open. The immediate aim is to connect operating conditions with the energy consequence and with the document needed to resolve uncertainty. A rerun should retain the same input file, time step and energy boundary, or make the changed assumption explicit.