Table of Contents
To assess optimizer losses in PVsyst, compare two runs with the same modules, weather and geometry. Report the change in electrical shading or mismatch loss, the energy lost during optimization and the effect of the device limits. Then use a common delivery boundary to compare net production. A benefit in one part of the loss diagram can be smaller than the losses introduced elsewhere.
What the optimizer changes
A power optimizer is a DC converter between the module and the string. It can allow the module to operate at a different voltage and current from the point it would have without optimization. The outputs of devices in a series string share a common current. The devices adjust their operating points within their electrical limits. Whether this recovers power depends on the differences between module operating conditions and on the electrical arrangement.
Shading reduces the light reaching the covered part of the array. It can also create an additional electrical effect through the interaction of modules or cell groups. Optimization can change the electrical effect for a specified configuration. If evaluating the optimizer is the objective, the shade geometry and timing should be the same in both runs. Review linear and electrical shading losses in PVsyst before changing the equipment model.
An improvement in the operation of one shaded string does not imply the same yield change in unshaded strings. Which strings share an input and how their operating voltages differ can affect the outcome. Record how the simulation ties each group to the string diagram and what the shade model represents. This lets the reviewer assess whether the case covers the affected section rather than treating a single condition as representative of the whole roof.
Locate the distinct optimizer losses
In the current PVsyst model, the optimizer effect is calculated after array losses and before the DC wiring resistance. The model does not provide a separate optimizer setting for wiring loss between the module and the optimizer. If that segment is significant, document its treatment and establish a consistent basis for both comparisons. Check which cable sections are already represented before adding any independent estimate to the totals.
Under ordinary operating conditions, the optimizer has a conversion efficiency. Its model can depend on input voltage and the output-to-input voltage ratio. A limit on input power, voltage or current can also move the operating point away from the module maximum. The resulting additional loss belongs to the limit rather than ordinary conversion. The particular equipment's official documentation and compatibility information determine what the model should represent.
| Variable | What to review |
|---|---|
| ShdElec and MisLoss | Electrical shading and array mismatch |
| OP_Oper | Operating efficiency loss |
| OP_Pmin, OP_Pmax | Lower power threshold and overload |
| OP_Vmin, OP_Vmax | Lower and upper optimizer voltage limits |
| OhmLoss | DC wiring loss |
The available outputs depend on the model and software version. When comparing runs, keep the energy unit, time step and calculation boundary visible. OP_Oper concerns the optimizer. The similarly named inverter efficiency record is at a different stage. Review the PVsyst loss diagram and the variables in the selected export so that losses already included in one subtotal do not receive a second entry.
A worked example before the DC cable
Use a common boundary before the downstream wiring. The baseline delivers 100 kWh to that point over a hypothetical period. With an optimizer, suppose the incoming electrical recovery is 2.6 kWh and device limits reduce the available balance by 0.9 kWh. The result before conversion is 101.7 kWh. Using an illustrative conversion multiplier of 0.985 gives 100.1745 kWh at the common boundary. This is an arithmetic exercise with assumed values, not a measurement or an equipment efficiency guarantee.
If the limits instead reduce the available energy by 1.4 kWh, 101.2 × 0.985 gives 99.682 kWh. A benefit at the module stage is present in both cases. In the second it is outweighed by the assumed device limitations and conversion. The downstream current and its cable effects may change as well. Calculate those separately when assessing energy after the inverter at the same output boundary. These numbers do not identify the outcome of a real installation.
Decide whether a small difference is material
A small difference in a worked example can be smaller than the uncertainty in the shade or efficiency assumptions. Look at the intervals contributing most to the result. For example, the time when a building casts a shadow may differ from the time when site demand peaks. Start with energy at the sequence of conversion boundaries, then look separately at the ability of the business to use it. A gain in production and a gain in useful on-site energy are distinct results. The question affects which periods and measurements matter in the comparison.
An illustrative constant multiplier should not replace the efficiency curve of an identified device. Review how the selected model behaves over the operating range and which connections it represents. If a proposal calls for devices only on part of the array, establish which strings and modules are included. Check whether the simulation can represent that arrangement. A model of one optimizer on every module cannot automatically stand in for a partially equipped design.
Compare the two design variants
Save the layout, shading scene, weather file, module model and time settings. Match array area, module count and the assignment of strings to inverters. If the optimized proposal comes with a different inverter or wiring arrangement, keep those changes visible. The comparison of optimizers and microinverters addresses the separate equipment architecture choice. An optimizer loss review addresses what happens within the stated circuit and simulation assumptions.
Export selected intervals showing different conditions. Preserve the case settings, energy before the optimizer stage, individual limitations and energy at the agreed delivery boundary. Make it clear which inputs come from a drawing or supported equipment document and where assumptions remain. If design data changes for shading, circuit assignment or compatibility, update both cases or mark the difference before comparing their output. Keeping the old case helps the project team explain the effect of each revision.
Where the result is close, compare more than the annual total. Examine whether the crossover follows a specific roof section, an equipment limit or an assumption about array mismatch. A small annual change may hide a few intervals with significant differences. On the other hand, a conspicuous power gap in a selected hour may contribute little to the annual energy estimate. Use the data resolution and time period that fit the intended decision.
Verify the output against the proposed configuration
Keep a device list with the model, including which strings are equipped and which layout revision is being assessed. If the final equipment is still being selected, identify the assumed operating data rather than leaving an efficiency figure unexplained. For the arithmetic example above, the pre-conversion energy required to exceed the 100 kWh baseline is about 101.523 kWh at the assumed multiplier. That threshold applies only to the example. A real comparison uses the changing efficiency profile and operating points.
The downstream cable can have the same length and a different operating current across two optimizer scenarios. Compare the outcome after the downstream AC conversion at a common point when deciding which system delivers more energy. Document any coincident export limit or inverter constraint that could change the net result.
For commercial solar design, hand over the two simulations and the outstanding questions about exact equipment and circuit coverage. Expected losses and yield depend on the configuration, the site and the operating conditions. A traceable comparison helps the engineering team identify where more precise inputs would make a difference and what needs confirmation before an equipment purchase.